18
Technical Data
Fluid
mineral oil according to DIN/ISO. For other fluid types, please contact the factory
Construction
– shut-off valve
– pressure relief
– manually-operated discharge valve
– electrically-operated discharge valve
ball valve
poppet-type valve with damping poppet-type valve
poppet-type valve (where fitted)
-15°C to +80°C
Operating temperature
10 to 800 mm2/s
Viscosity
U=24VDC, 105VDC (for 115V/60 Hz AC supply), P=26W,100% ED, IP 65 to DIN 40050, connector to DIN
43650 type A
Electrical discharge
accumulator port A facing upwards
Mounting position
M8 to grade 10.9, max. torque 26 + 4Nm
Mounting screws (not supplied)
-30°C to +80°C
Ambient temperature
black zinc phosphated
Finish
350 bar
Max. operating pressure
Nitrile
Seal material
558