Page 161 - Fluid Power
P. 161

Hydraulics
For any other Part Numbers or Types you require please contact your local Brammer Sales & Service Centre.
Technical Data
PV016 PV020 PV023 PV028 PV032 PV040 PV046 Framesize 1111222
With thru drive for single and multiple pumps
Swash plate type for open circuit
Technical Features
• Low noise level
• Fast response
• Service-friendly
• High self-priming speed
• Compact design
• Thru drive for 100% nominal torque
PV140 PV180 PV063 PV080 PV092 PV270 PV360 Framesize 4433355
Max. Displacement
Output flow at 1500 rpm
Nominal pressure pN
Max. pressure pmax at 20% working cycle
Case drain pressure, continuous
Case drain pressure, max. peak
Min. Inlet pressure, abs. Max. Inlet pressure
Input power at 1500 rpm and 350 bar
Max speed at 1 bar inlet pressure
Moment of inertia Weight
[cm3/rev.] 16 [l/min] 24 [bar] 350
[bar] 420 [bar] 0.5
[bar] 2.0 [bar] 0.8
20 23 28 30 34.5 42 350 350 350
420 420 420 0.5 0.5 0.5
2.0 2.0 2.0
32 40 46 48 60 69 350 350 350
420 420 420 0.5 0.5 0.5
2.0 2.0 2.0
Max. Displacement
Output flow at 1500 rpm
Nominal pressure pN
Max. pressure pmax at 20% working cycle
Case drain pressure, continuous
Case drain pressure, max. peak
Min. Inlet pressure, abs.
Max. Inlet pressure
Input power at 1500 rpm and 350 bar
Max speed at 1 bar inlet pressure
Moment of inertia Weight
[cm3/rev.] 140 180 [l/min] 270 405 [bar] 350 350
[bar] 420 420 [bar] 0.5 0.5
[bar] 2.0 2.0
[bar] 0.8 0.8 [bar] 16 16
[kW] 136 175
63 80 92 94.5 120 138 350 350 350
420 420 420 0.5 0.5 0.5
2.0 2.0 2.0
0.8 0.8 0.8 16 16 16
61.5 78 89.5
270 360 405 540 350 350
420 420 0.5 0.5
2.0 2.0
0.8 0.8 16 16
262 350
0.8 0.8 0.8
16 16 16 16 16 16 16
18
0.8 0.8 0.8
[bar] [kW]
15.5 19.5
22.5 27.5 31
39 45
[rpm] 3000 3000 3000 3000 2800 2800 2800
[kgm2] 0.0017 0.0017 0.0017 0.0017 0.0043 0.0043 0.0043 [kg] 19 19 19 19 30 30 30
[rpm] 2400 2200 2800 2500 2300 1800 1750
[kgm2] 0.030 0.030 0.103 [kg] 90 90 60 60 60 172 180
General Information
Fluid recommendations
Premium quality hydraulic mineral fluid is recomended, like HLP oils to DIN 51524, part 2. Brugger- value has to be 30 N/ mm2 minimum for general application and 50 N/mm2 for heavily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with
DIN 51 347-2. See also Document HY30-3248/UK Parker Hydraulic Fluids.
Viscosity
The normal operating viscosity should range between 16 and 100 mm2/s (cSt). Max. start-up viscosity is 800 mm2/s (cSt).
Filtration
For maximum pump and system component functionality and life, the system should be protected from contamination by
effective filtration. Fluid cleanliness should be in accordance with ISO classification ISO 4406:1999. The quality of filter elements should be in accordance with ISO standards. General hydraulic systems for satisfactory operation: Class 20/18/15, according to ISO 4406:1999 Recommended cleanliness for maximum component life and functionality: Class 18/16/13, according to ISO 4406:1999
Seals
Check hydraulic fluid specification for chemical resistance of seal material. Check temperature range of seal material and compare with max. system and ambient temperature. N - Nitrile -40 ... +90 °C
Note: The highest fluid temperature will be at the drain port of the pump, up to 25 °C higher than in the reservoir.
Contact Brammer on 0870 240 2100 Hydraulics 531
Hydraulics


































































































   159   160   161   162   163